W25Q80BW
8.6 AC Electrical Characteristics
DESCRIPTION
Clock frequency for all instructions
except Read Data instruction (03h)
Clock frequency for Read Data instruction (03h)
& Continuous Read Mode
SYMBOL
F R
f R
ALT
f C
MIN
D.C.
D.C.
SPEC
TYP
MAX
80
50
UNIT
MHz
MHz
Clock High, Low Time
for all instructions except Read Data (03h)
Clock High, Low Time
for Read Data (03h) instruction
Clock Rise Time peak to peak
Clock Fall Time peak to peak
t CLH 1 ,
t CLL 1(1)
t CRLH ,
t CRLL (1)
t CLCH (2)
t CHCL (2)
6
8
0.1
0.1
ns
ns
V/ns
V/ns
/CS Active Setup Time relative to CLK
/CS Not Active Hold Time relative to CLK
Data In Setup Time
Data In Hold Time
/CS Active Hold Time relative to CLK
/CS Not Active Setup Time relative to CLK
/CS Deselect Time (for Array Read ? Array Read)
/CS Deselect Time (for Erase or Program ? Read
t SLCH
t CHSL
t DVCH
t CHDX
t CHSH
t SHCH
t SHSL 1
t SHSL 2
t CSS
t DSU
t DH
t CSH
t CSH
5
5
2
5
5
5
10
50
ns
ns
ns
ns
ns
ns
ns
ns
Status Registers)
Volatile Status Register Write Time
50
Output Disable Time
Clock Low to Output Valid
Clock Low to Output Valid (for Read ID instructions)
Output Hold Time
/HOLD Active Setup Time relative to CLK
t SHQZ (2)
t CLQV 1
t CLQV 2
t CLQX
t HLCH
t DIS
t V 1
t V 2
t HO
0
5
7
7
7.5
ns
ns
ns
ns
ns
Continued – next page
- 62 -